Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Br J Clin Pharmacol ; 88(10): 4540-4551, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35508762

RESUMO

AIMS: The absorption, metabolism and excretion of opicapone (2,5-dichloro-3-(5-[3,4-dihydroxy-5-nitrophenyl]-1,2,4-oxadiazol-3-yl)-4,6-dimethylpyridine 1-oxide), a selective catechol-O-methyltransferase inhibitor, were investigated. METHODS: Plasma, urine and faeces were collected from healthy male subjects following a single oral dose of 100 mg [14 C]-opicapone. The mass balance of [14 C]-opicapone and metabolic profile were evaluated. RESULTS: The recovery of total administered radioactivity averaged >90% after 144 hours. Faeces were the major route of elimination, representing 70% of the administered dose; 5% and 20% were excreted in urine and expired air, respectively. The Cmax of total radioactivity matched that of unchanged opicapone, whereas the total radioactivity remained quantifiable for a longer period, attributed to the contribution of opicapone metabolites, involving primarily 3-O-sulfate conjugation (58.6% of total circulating radioactivity) at the nitrocatechol ring. Other circulating metabolites, accounting for <10% of the radioactivity exposure, were formed by glucuronidation, methylation, N-oxide reduction and gluthatione conjugation. Additionally, various other metabolites resulting from combinations with the opicapone N-oxide reduced form at the 2,5-dichloro-4,6-dimethylpyridine 1-oxide moiety, including nitro reduction and N-acetylation, reductive opening and cleavage of the 1,2,4-oxadiazole ring and the subsequent hydrolysis products were identified, but only in faeces, suggesting the involvement of gut bacteria. CONCLUSION: [14 C]-opicapone was fully excreted through multiple metabolic pathways. The main route of excretion was in faeces, where opicapone may be further metabolized via reductive metabolism involving the 1,2,4-oxadiazole ring-opening and subsequent hydrolysis.


Assuntos
Inibidores de Catecol O-Metiltransferase , Oxidiazóis , Administração Oral , Inibidores de Catecol O-Metiltransferase/farmacocinética , Fezes , Voluntários Saudáveis , Humanos , Masculino , Oxidiazóis/farmacocinética
3.
J Neuroeng Rehabil ; 13: 24, 2016 Mar 12.
Artigo em Inglês | MEDLINE | ID: mdl-26969628

RESUMO

BACKGROUND: There is growing interest in having objective assessment of health-related outcomes using technology-based devices that provide unbiased measurements which can be used in clinical practice and scientific research. Many studies have investigated the clinical manifestations of Parkinson's disease using such devices. However, clinimetric properties and clinical validation vary among the different devices. METHODS: Given such heterogeneity, we sought to perform a systematic review in order to (i) list, (ii) compare and (iii) classify technological-based devices used to measure motor function in individuals with Parkinson's disease into three groups, namely wearable, non-wearable and hybrid devices. A systematic literature search of the PubMed database resulted in the inclusion of 168 studies. These studies were grouped based on the type of device used. For each device we reviewed availability, use, reliability, validity, and sensitivity to change. The devices were then classified as (i) 'recommended', (ii) 'suggested' or (iii) 'listed' based on the following criteria: (1) used in the assessment of Parkinson's disease (yes/no), (2) used in published studies by people other than the developers (yes/no), and (3) successful clinimetric testing (yes/no). RESULTS: Seventy-three devices were identified, 22 were wearable, 38 were non-wearable, and 13 were hybrid devices. In accordance with our classification method, 9 devices were 'recommended', 34 devices were 'suggested', and 30 devices were classified as 'listed'. Within the wearable devices group, the Mobility Lab sensors from Ambulatory Parkinson's Disease Monitoring (APDM), Physilog®, StepWatch 3, TriTrac RT3 Triaxial accelerometer, McRoberts DynaPort, and Axivity (AX3) were classified as 'recommended'. Within the non-wearable devices group, the Nintendo Wii Balance Board and GAITRite® gait analysis system were classified as 'recommended'. Within the hybrid devices group only the Kinesia® system was classified as 'recommended'.


Assuntos
Acelerometria/instrumentação , Monitorização Ambulatorial/instrumentação , Doença de Parkinson/fisiopatologia , Humanos , Doença de Parkinson/reabilitação , Reprodutibilidade dos Testes
4.
Front Neurol ; 7: 27, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27014181

RESUMO

There is limited information available concerning the treatment of daytime somnolence associated with Parkinson's disease (PD); the most frequently applied therapeutic strategies include decreasing the dose of dopamine agonists or adding potential wake-promoting agents. There is recent data from a placebo-controlled trial concluding on a non-significant trend in favor of caffeine. We aimed to evaluate the efficacy of espresso-coffee in the treatment of daytime somnolence in PD. To evaluate the efficacy of espresso-coffee in the treatment of daytime somnolence in PD, we have conducted multiple single-patient (n-of-1) clinical trials comparing regular espresso coffee to decaffeinated coffee in PD patients presenting moderate to severe daytime somnolence defined as an Epworth Sleepiness Scale score >9. Each single-patient (n-of-1) trial included a sequence of three crossovers (two treatment periods separated by two days of washout). Four patients were included in the studies and three completed the three pairs of treatment periods. In two of the four patients, espresso coffee was considered beneficial. This study concludes that multiple single patient trials are feasible in PD and suggests that espresso-coffee may have a beneficial effect on daytime somnolence in some patients. These results cannot be generalized beyond the patients included in these trials.

5.
Water Res ; 85: 244-54, 2015 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-26340062

RESUMO

Monitoring of nitrite is essential for an immediate response and prevention of irreversible failure of decentralized biological urine nitrification reactors. Although a few sensors are available for nitrite measurement, none of them are suitable for applications in which both nitrite and nitrate are present in very high concentrations. Such is the case in collected source-separated urine, stabilized by nitrification for long-term storage. Ultraviolet (UV) spectrophotometry in combination with chemometrics is a promising option for monitoring of nitrite. In this study, an immersible in situ UV sensor is investigated for the first time so to establish a relationship between UV absorbance spectra and nitrite concentrations in nitrified urine. The study focuses on the effects of suspended particles and saturation on the absorbance spectra and the chemometric model performance. Detailed analysis indicates that suspended particles in nitrified urine have a negligible effect on nitrite estimation, concluding that sample filtration is not necessary as pretreatment. In contrast, saturation due to very high concentrations affects the model performance severely, suggesting dilution as an essential sample preparation step. However, this can also be mitigated by simple removal of the saturated, lower end of the UV absorbance spectra, and extraction of information from the secondary, weaker nitrite absorbance peak. This approach allows for estimation of nitrite with a simple chemometric model and without sample dilution. These results are promising for a practical application of the UV sensor as an in situ nitrite measurement in a urine nitrification reactor given the exceptional quality of the nitrite estimates in comparison to previous studies.


Assuntos
Reatores Biológicos , Nitritos/urina , Espectrofotometria Ultravioleta/métodos , Urina/química , Modelos Químicos , Nitrificação
6.
BMC Neurol ; 15: 89, 2015 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-26059091

RESUMO

BACKGROUND: Currently, assessment of symptoms associated with Parkinson's disease is mainly performed in the clinic. However, these assessments have limitations because they provide only a snapshot of the condition. METHODS: The feasibility and usability of an objective, continuous and relatively unobtrusive system (SENSE-PARK System), which consists of wearable sensors (three worn during the day and one worn at night), a smartphone-based App, a balance board and computer software, was tested 24/7 over 12 weeks in a study including 22 PD patients. During the first four weeks of the study, patients did not get feedback about their performance, during the last eight weeks they did. The study included seven clinical visits with standardized interviews, and regular phone contact. The primary outcome was the number of drop-outs during the study. As secondary outcomes, the Post-Study System Usability Questionnaire (PSSUQ), score and information obtained from the standardized interviews were used to evaluate the usability of the system. RESULTS: All patients completed the study. The participants rated the usability of the SENSE-PARK System with a mean score of 2.67 (±0.49) on the PSSUQ. The interviews revealed that most participants liked using the system and appreciated that it signaled changes in their health condition. CONCLUSIONS: This 12 week controlled study demonstrates that the acceptance level of PD patients using the SENSE-PARK System as a home-based 24/7 assessment is very good. Particular emphasis should be given to a user-friendly design. Motivation to wear such a system can be increased by providing direct feedback about the individual health condition.


Assuntos
Monitorização Ambulatorial/métodos , Doença de Parkinson/diagnóstico , Aceitação pelo Paciente de Cuidados de Saúde , Idoso , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Ambulatorial/instrumentação , Estudos Multicêntricos como Assunto , Cooperação do Paciente , Satisfação do Paciente , Projetos Piloto
7.
J Parkinsons Dis ; 5(2): 281-90, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25663101

RESUMO

BACKGROUND: Parkinson's disease (PD) is a neurodegenerative disorder with fluctuating symptoms. To aid the development of a system to evaluate people with PD (PwP) at home (SENSE-PARK system) there was a need to define parameters and tools to be applied in the assessment of 6 domains: gait, bradykinesia/hypokinesia, tremor, sleep, balance and cognition. OBJECTIVE: To identify relevant parameters and assessment tools of the 6 domains, from the perspective of PwP, caregivers and movement disorders specialists. METHODS: A 2-round Delphi study was conducted to select a core of parameters and assessment tools to be applied. This process included PwP, caregivers and movement disorders specialists. RESULTS: Two hundred and thirty-three PwP, caregivers and physicians completed the first round questionnaire, and 50 the second. Results allowed the identification of parameters and assessment tools to be added to the SENSE-PARK system. The most consensual parameters were: Falls and Near Falls; Capability to Perform Activities of Daily Living; Interference with Activities of Daily Living; Capability to Process Tasks; and Capability to Recall and Retrieve Information. The most cited assessment strategies included Walkers; the Evaluation of Performance Doing Fine Motor Movements; Capability to Eat; Assessment of Sleep Quality; Identification of Circumstances and Triggers for Loose of Balance and Memory Assessment. CONCLUSIONS: An agreed set of measuring parameters, tests, tools and devices was achieved to be part of a system to evaluate PwP at home. A pattern of different perspectives was identified for each stakeholder.


Assuntos
Avaliação das Necessidades , Doença de Parkinson/diagnóstico , Atividades Cotidianas , Cuidadores , Técnica Delphi , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doença de Parkinson/complicações , Doença de Parkinson/fisiopatologia , Doença de Parkinson/psicologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...